METTLER TOLEDO IND560 IND560x Membrane Keyboard Keypad Replacement Repair


Mettler-Toledo IND560 IND560x Membrane Keypad Switch Repair Replacement

The IND560 has specific bits to allow the PLC to confirm that data was received without interrupt and the IND560 Membrane Keyboard is not in an error condition. It is important to monitor these bits. Any PLC code should use them to confirm the integrity of the data received for the IND560. Refer to data charts in Appendix A and Appendix B for specific information regarding the Data OK, Update in Progress, Data Integrity bits and their usage.
The integer and division formats allow bi-directional communication of discrete bit encoded information or 16 bit binary word numerical values. The IND560 provides one quarter rack of data per Message Slot when in integer or division mode.
The floating-point format allows bi-directional communication of discrete bit encoded information or numeric data encoded in IEEE 754, single precision floating point format. The IND560 Membrane Keypad provides one-half rack of data per Message Slot when in floating point mode.


VICPAS supply Mettler Toledo IND560 IND560x Operator Panel Keypad with 365 days warranty and support Urgent Worldwide Shipping. The IND560x Keypad Membrane terminal is a high-performance single- or multiple-range weighing terminal designed for use with analog load cells or high-precision IDNet scale interfaces. The IND560x Switch Membrane Terminal delivers precision measurement data from milligrams to tons in a single cost effective package that easily integrates into existing systems.
Power options include an external power supply that converts high-level AC voltage to intrinsically safe DC voltages and is still suitable for installation inside the hazardous area. An external battery for use in mobile applications is also available for use with the harsh/analog model of the IND560x.




Specifications:

The table below describes the parameters of the Mettler-Toledo IND560 IND560x Operator Keyboard HMI Parts.

Approvals: Weights and Measures
Dimensions (l × w × d): 265 mm × 160 mm × 92 mm
Operating Temperature: -10 °C to +40 °C
Part Number: IND560 IND560x
Warranty: 365 Days
Brand: Mettler Toledo
Dimensions (l × w × d): 160 mm x 265 mm × 92 mm
Keypad: 25 keys; 26 keys;
Power: AC version
Storage Temperature: -20 °C to +60 °C


Related Mettler Toledo HMI Part No. :

METTLER TOLEDO HMI Description Inventory status
IND360 Base Harsh Mettler-Toledo Membrane Keyboard Keypad Replacement In Stock
IND360 Base Panel Mettler Toledo Membrane Keypad Replacement Repair Available Now
IND360 Tank/Vessel Mettler Toledo Membrane Keypad Switch Replacement In Stock
IND560 METTLER TOLEDO HMI Membrane Keyboard Keypad Replacement Available Now
IND560x Mettler Toledo HMI Terminal Keypad Replacement Repair In Stock
IND570 Mettler Toledo Operator Panel Keypad HMI Replacement Repair In Stock
IND570xx METTLER TOLEDO Operator Keyboard HMI Repair Replacement In Stock
IND690 Mettler-Toledo HMI Keyboard Membrane Replacement Repair Available Now
IND780 Mettler-Toledo HMI Keypad Membrane Replacement Available Now
IND890 Mettler Toledo Switch Membrane Touch Screen Repair In Stock
IND890SQC METTLER TOLEDO Touch Panel Membrane Switch Replacement In Stock
IND930 METTLER TOLEDO Protective Film Repair Replacement Available Now
IND970 Mettler Toledo Membrane Keypad Switch Replacement Repair In Stock
ISC469 Mettler-Toledo HMI Terminal Keypad Replacement Repair Available Now
Mettler-Toledo Terminal Description Inventory status


Mettler Toledo HMI Manuals PDF Download:

  • IND560 PLC Interface Manual
  • IND560 Terminal Installation Manual - Mettler Toledo
  • IND560 User's Guide - Mettler Toledo
  • IND560-PLC-Interface-Manual
  • IND560x Technical Manual
  • IND560x Weighing Terminal - User's Guide - Mettler Toledo
  • IND560x Weighing Terminal
  • Mettler Toledo IND560 Technical Manual
  • Mettler Toledo Industrial-Catalog-2018

  • FAQ:

    Question: How to clean the IND560 IND560x Switch Membrane Terminal?

    Answer:
    Use a soft, clean cloth and mild glass cleaner. Do not spray cleaner directly onto IND231 IN236 Operator Keyboard terminal.
    Do not use industrial solvents such as acetone.

    Common misspellings: 

    IND560 IN560x
    ID560 IND560x
    IND560 IND56x0
    IND56o IND560x
    IND560 INDD560x
    Productos Relacionados
      Escriba su mensaje por favor
      *Email
      Teléfono
      *Título
      *Contenido
      Subir
      • Solo admite .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, máximo 20M
      Ponte en contacto con nosotros
      Dirección de la empresa: 5Floor-17. N ° 332. Gangkou Road, Xin Tang Town, ZengCheng, Guangzhou City, Guangdong Province, PR China

      TECNOLOGÍA CO., LTD DE GUANGZHOU VICPAS TOUCH

      Tel / Fax: +86158 7652 5394

      sales@vicpas.com
      suscripción